Problem
As a data center operator you need to maximize the
performance, availability and life of mission critical assets.
This is becoming more and more of a challenge as
business computing demand and data center energy density increase.
Data center monitoring and control is key to maintain
uptime
while optimizing cooling energy.

Solution
Sensor based environmental monitoring provides a real-time picture of
the state of the data center, detecting potential problems and allowing
implementation of energy efficiency programs.
Spinwave's environmental monitoring solution features:
-
Low installation cost
Wireless: Mount sensors easily at required
locations. Standard batteries can power sensors for years.
No new software required:
Wireless sensor networks integrate with virtually any existing
building automation (via Modbus, BACnet, LON) system or network
management application (via SNMP) through a
protocol
gateway.
-
High Reliability Mesh Network
Mesh network
wireless protocol outsmarts changing RF interference with self-adapting frequency agility.
Data quality indicator flags low-battery or
communication time-out.
-
Flexible and scalable
The network is scalable from a few to hundreds of
sensors. Wireless sensors can be easily moved as requirements change. A
broad range of sensors are available, including: Temperature (one
or
more points),
Relative Humidity,
Pulse
(power/gas/water meters),
Voltage
(to interface with pressure and air flow sensors, leak detectors).
Repeaters
may be added to extend the RF
range up to an additional 3,500 feet.
-
Proven
Products are used by leading data center operators
world-wide.
Architecture

Products
|
Part Number |
Description |
|
|
Wireless Sensors – Temperature |
|
SWS-T |
Wireless temperature sensor, on-board thermistor |
|
SWS-TEXT |
Wireless transceiver with external 10K, type III thermistor, 10’
leads included |
|
SWS-T-2EXT |
Wireless transceiver with on-board thermistor and 2 external
10K, type III thermistors, 10’ leads, and mounting magnets
included |
|
SWS-3TEXT |
Wireless transceiver with 3 external external 10K type III
thermistors, 10’ leads, and mounting magnets included |
|
|
Wireless Sensors – Relative Humidity |
|
SWS-TRH |
Wireless zone temperature & relative humidity sensor, 1.8% RH |
|
SWS-TRH-2TEXT |
Wireless transceiver with on-board temperature & relative
humidity sensor (1.8% RH) and 2 external 10K, type III
thermistors, 10’ leads, and mounting magnets included |
|
|
Wireless Sensors – Analog Inputs |
|
SWS-3AI |
Wireless analog input module with three 0-5VDC inputs |
|
|
Wireless Sensors – Digital Input |
|
SWS-DI |
Wireless Digital Input (dry contact) |
|
|
Interface Options |
|
SWRF-LON |
Receiver & LONWORKS interface, 3 ft. radio cable |
|
SWRF-BACNET-IP |
Receiver & BACnet IP interface, 3 ft. radio cable |
|
SWRF-BACNET-MSTP |
Receiver & BACnet MS/TP interface, 3 ft. radio cable |
|
SWRF-MODBUS-TCP |
Receiver & Modbus TCP interface, 3 ft. radio cable |
|
SWRF-MODBUS-RTU |
Receiver & Modbus RTU interface, 3 ft. radio cable |
|
SWRF-SNMP |
Receiver & SNMP interface, 3 ft. radio cable |
|
|
Wireless Repeater/Router |
|
SWRP |
Wireless mesh repeater/router (requires power supply) |
|
|
|
|